Gefen GEF-3GSDI-16416 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Conversores em série Gefen GEF-3GSDI-16416. Gefen GEF-3GSDI-16416 User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - 16x16 3GSDI Matrix

1080P16x16 3GSDI MatrixGEF-3GSDI-16416User Manualwww.gefenpro.com

Página 2 - ASKING FOR ASSISTANCE

7PANEL DESCRIPTIONSBack Panel1 Reference In ConnectorConnect an external reference to this connector. Bi-level (black burst) and tri-level sync are

Página 3 - CONTENTS

8How to Connect the 16x16 3GSDI Matrix1. Connect up to 16 3G-SDI source devices to the 3G-SDI inputs on the rear panel of the 16x16 3GSDI Matrix usin

Página 4 - INTRODUCTION

9The Standby ScreenThe front panel of the 16x16 3GSDI Matrix has a 16 character 2 line LCD display. This display will shows the current routing status

Página 5 - OPERATION NOTES

10CONNECTING AND OPERATING THE 16X16 3GSDI MATRIXSwitching between RS-232 and RS-485 ProtocolsPress the ► button to display the serial interface selec

Página 6 - FEATURES

11In the example below, TERMINATION Off has been selected. The LCD will now show that the RS-485 protocol has been selected, along with the terminati

Página 7 - PANEL LAYOUT

12Displaying the Routing StatusFrom the main screen, press the Select button. When the arrow cursor is next to OUTPUT, pressing the ◄ or ► buttons on

Página 8

13IR REMOTE DESCRIPTIONRMT-16416IRRemote Control Unit1 Activity IndicatorThis LED will be activated momentarily each time a button is pressed.2 Displ

Página 9

14Installing the RMT-16416IR Battery1. Remove the battery cover on the back of the IR Remote Control unit.2. Insert the included battery into the op

Página 10 - PANEL DESCRIPTIONS

15IR REMOTE CONFIGURATIONHow to Resolve IR Code Confl ictsIn the event that IR commands from other remote controls interfere with the supplied IR Remot

Página 11 - GEF-3GSDI-16416

16What features are available via the RS-232 serial communications port?The 16x16 3GSDI Matrix can accept commands through the RS-232 serial communica

Página 12

ASKING FOR ASSISTANCERev A3Technical Support:Telephone (818) 772-9100 (800) 545-6900Fax (818) 772-9120Technical Support Hours:8:00 AM - 5:00 PM

Página 13

17RS-232 SERIAL CONTROLRS-232 FeaturesRS-232 remote functions are used to control this product’s features. Features include input / output routing and

Página 14

18RS-232 SERIAL CONTROL#PRREFTABLE FunctionThe #PRREFTABLE function displays the Reference In data table (timings) which are recognized by the 16x16 3

Página 15

19RS-232 SERIAL CONTROL#SNETMASK FunctionThe #SNETMASK function specifi es a new net mask.Syntax:#SNETMASK param1 param2 param3 param4Parameters:param1

Página 16 - IR REMOTE DESCRIPTION

20RS-232 SERIAL CONTROL#SPORT FunctionSpecifi es a new port for a Web server.Syntax:#SPORT param1Parameters:param1 Port [0 - 255]Notes:A reboot is

Página 17 - IR REMOTE INSTALLATION

21RS-232 SERIAL CONTROLGeneral FunctionsFunction Description#ACTIVEBOLO Enables the boot loader#FADEFAULT Sets IP Confi gurations to default settings#R

Página 18 - IR REMOTE CONFIGURATION

22RS-232 SERIAL CONTROL#RMTIRADD FunctionThe #RMTIRADD function set the remote IR channel.Syntax:#RMTIRADD param1Parameters:param1 IR channel

Página 19 - RS-232 SERIAL INTERFACE

23CommandsCommand DescriptionM Returns the current routing status of matrixR Routing commandS Routes a single input to all outputsM CommandThe M comma

Página 20 - RS-232 SERIAL CONTROL

24RS-232 SERIAL COMMANDSS CommandThe S command routes a single input to all 16 3GSDI outputs.Syntax:s param1Parameters:param1 Input [1 - 16]Note

Página 21

25IP CONTROLThe GefenPRO 16x16 3GSDI Matrix supports IP-based control using an integrated Web interface. To access this feature, an IP address, subnet

Página 22

26IP CONTROLMaskingThe Masking page is used to hide an output from displaying any video. From this page, all outputs can be set to “Active” or “Mask”.

Página 23

CONTENTS1 Introduction2 Operation Notes3 Features4 Panel Layout4 Front Panel5 Front Panel Descriptions6 Panel Layout6 Back Panel7 Back Panel

Página 24

27IP CONTROLIP Confi gurationThe IP Confi guration page is used to set the IP settings that will be used to access the Web interface. The following item

Página 25

28IP CONTROLBackup / RestoreThe Backup/Restore page is used to backup and restore complete setup confi gurations.Note: This feature will be implemente

Página 26

29FIRMWARE UPDATEFirmware Update ProcedureTo Begin the update procedure the unit’s Boot Loader must be activated. To activate the Boot Loader please f

Página 27 - RS-232 SERIAL COMMANDS

30FIRMWARE UPDATEFollow the on-screen instructions to complete the fi rmware update process:1. Press [1] on the computer keyboard to begin downloading

Página 28 - IP CONTROL

31WARNING MESSAGESSystem FailureIn the case of a critical malfunction, the following warning message will be displayed on the Main Display:If the 16x1

Página 29

32RACK MOUNT SAFETY INFORMATIONa. Maximum recommended ambient temperature: 45 ˚Cb. Increase the air fl ow to maintain the temperature inside the rack

Página 30

33Input / Output • SDI (SMPTE 259MI up to 360 Mbps)• HD-SDI (SMPTE 292M up to 1.485 Gbps)• 3G-SDI (SMPTE 424M/425M up to 3.0 Gbps)Supported Formats

Página 31

34WARRANTYGefen warrants the equipment it manufactures to be free from defects in material and workmanship.If equipment fails because of such defects

Página 32 - FIRMWARE UPDATE

35LICENSINGlwIP is licenced under the BSD licence:Copyright (c) 2001-2004 Swedish Institute of Computer Science.All rights reserved.Redistribution and

Página 33

Rev A3Pb20600 Nordhoff St., Chatsworth CA 913111-800-545-6900 818-772-9100 fax: 818-772-9120www.gefenpro.com [email protected]

Página 34 - WARNING MESSAGES

1Congratulations on your purchase of the 16x16 3GSDI Matrix. Your complete satisfaction is very important to us.GefenGefen delivers innovative, progre

Página 35 - RACK MOUNT SAFETY INFORMATION

2READ THESE NOTES BEFORE INSTALLING OROPERATING THE 16X16 3GSDI MATRIX• There is no internal scaling in the 16x16 3GSDI Matrix. All of the attached m

Página 36 - SPECIFICATIONS

3Features• Increases productivity• Supports resolutions up to 1080p, 1920x1200, and 2K.• Front panel control buttons for local switching.• Status L

Página 37 - PRODUCT REGISTRATION

4Front PanelPANEL LAYOUT4 5 6213

Página 38 - LICENSING

5PANEL DESCRIPTIONSFront Panel1 LCD DisplayDisplays the current routing status of the Matrix and is also used to manage source routing.2 Power SwitchT

Página 39

6PANEL LAYOUTBack Panel4 58961327

Comentários a estes Manuais

Sem comentários